GenomeLab DTCS Quick Start Kit
|
|
|
|
The GenomeLab DTCS Quick Start Kit simplifies the process of reaction set up by using a reagent master-mix --reducing the number of pipetting steps from 10 to 4 over individual reagent vial kits, while using larger transfer volumes to reduce pipetting error. The master-mix of this dye terminator cycle sequencing (DTCS) kit incorporates reaction components, including DNA polymerase, dNTPs, dye terminators (ddUTP, ddGTP, ddCTP, ddATP) and reaction buffer, into a convenient, single tube for ease of use. pUC18 control template, M13 (-47) sequencing primer, sample loading solution, glycogen and mineral oil are also included in the kit. Each kit provides enough reagents to complete 100 sequencing reactions.
|
| Part No. |
Description |
| 608120
|
GenomeLab DTCS Quick Start Kit
|
|
|
|
|
GenomeLab Methods Development Kit
|
|
|
|
The GenomeLab Methods Development Kit provides two dye terminator sequencing chemistries in an individual reagent vial format, allowing for flexibility in performing sequencing reactions. Included in this kit are: thermostable DNA polymerase, dye terminators (ddUTP, ddGTP, ddCTP, ddATP), dNTP(I) and dNTP(G) solution, sequencing reaction buffer, pUC18 control template, M13 (-47) sequencing primer, glycogen, sample loading solution and mineral oil. Each kit provides enough reagents to complete 100 sequencing reactions.
|
| Part No. |
Description |
| 608000
|
GenomeLab Methods Development Kit
|
|
|
|
|
GenomeLab Separation Gel LPA-1
|
|
|
|
The GenomeLab linear polyacrylamide (LPA) denaturing gel assures high-resolution separations. Used for both DNA sequencing and fragment analysis. Packaged in a pre-mixed cartridge for quick reloading by operator.
|
| Part No. |
Description |
| 608010
|
GenomeLab Separation Gel LPA-1, 10mL (For use with CEQ 8000 and CEQ 2000XL)
One 10 mL cartridge is sufficient for 96 sequencing or fragment analysis runs. Storage temperature: 6° C
|
| 391438
|
GenomeLab Separation Gel LPA-1, 20mL (For use with CEQ 8800 Dual-Plate Format Only)
One 20 mL cartridge is sufficient for two 96-well plates for sequencing or fragment analysis runs. Storage temperature: 6° C
|
|
|
|
|
GenomeLab Separation Buffer
|
|
|
|
Each container has a twist top with convenient dropper tip and contains sufficient buffer (30 mL) to fill one flat-bottomed 96-well Buffer Plate. Storage temperature: 6° C
|
| Part No. |
Description |
| 608012
|
GenomeLab Separation Buffer, 4/pk
Each container has a screw top and a convenient pour tip and contains sufficient buffer (30 mL) to fill one Buffer Plate of 96 flat-bottom wells
|
|
|
|
|
GenomeLab DNA Capillary Array
|
|
|
|
Each array has eight capillaries, complete with inlet electrode cannula and detector array fitting
|
| Part No. |
Description |
| 608087
|
GenomeLab DNA Separation Capillary Array, 33 cm x 75 µm
Eight capillaries, 75 µm i.d., 33 cm long, complete with inlet electrode block and detector array fitting. Ready for easy installation into the CEQ Series for sequencing and/or fragment analysis. Storage temperature: 6° C.
|
| 608015
|
GenomeLab DNA Sequencing Capillary Array, 50 cm x 100 µm
Eight capillaries, 50 cm in length, 100 µm i.d.
Complete with inlet electrode block and detector array fitting. Ready for installation into the CEQ for sequencing applications. Requires long plenum.
|
|
|
|
|
GenomeLab DNA Test Sample
|
|
A set of fluorescently labeled DNA fragments of known sizes and defined spacing used to verify the resolution power of the CEQ fragment analysis system.
|
| Part No. |
Description |
| 608070
|
GenomeLab DNA Test Sample, 3 Vial/pk
Sequencing reaction products test sample in vials. Sufficient for 24 runs on the CEQ.
|
|
|
|
|
GenomeLab Sample Loading Solution
|
|
|
| Part No. |
Description |
| 608082
|
GenomeLab Sample Loading Solution (SLS), 6.0 mL
|
|
|
|
|
Sequencing Buffers, Templates, and Primer
|
|
|
| Part No. |
Description |
| 608074
|
GenomeLab Sequencing Reaction Buffer, 12 vials/pk
|
| 390289
|
GenomeLab Sequencing Control Template, 5 vials/pk
|
| 390285
|
GenomeLab -47 Sequencing Primer, 5 vials/pk
|
|
|
|
|
Sample Microtiter Plates
|
|
|
|
|
| Part No. |
Description |
| 609801
|
Sample Microtiter Plates, 25/pk
Package of 25 V-bottom thermocycler-compatible polypropylene plates with 200µL nominal volume to easily contain 40µL of sample. Recommended for use as the Capillary Electrophoresis sample plate.
|
| 609844
|
Beckman Coulter 96-Well Plates, Nonsterile, Without Lids, 100 pk
Capacity: 300 µL/well (packages of 100). Four packages of 25 each flat-bottom polystyrene plates. Recommended for use as the Capillary Electrophoresis Separation Buffer Plate.
|
|
|
|
|
Gel Waste Bottle
|
|
|
|
Used for automatic collection of purged gel after separations on the CEQ. Each bottle will hold 250 mL of waste gel, which is equivalent to approximately 50 plates of 96 runs each.
|
| Part No. |
Description |
| 974705
|
Gel Waste Bottle, 12/pk
|
|
|
|
|