| Part No. |
Description |
| 144660
|
OpCal Cartridge
|
| 144733
|
UV/VIS Upgrade Kit
|
| 149819
|
P/ACE MDQ DAD Upgrade Kit - Consists of DAD detector, DAD optics cable, and DAD board
|
| 144738
|
Blank Cartridge Assembly Kit - Contains cartridge body, 100 x 800 µm aperture, tubing kit, nuts, ferrules, and O-rings
|
| 144645
|
Cartridge Rebuilding Kit - Contains capillary length template, cleaving stone, rebuild instructions, O-rings, installation tool, and tweezers
|
| 970297
|
Cartridge Aperture O-Rings (quantity 2)
|
| 144689
|
Cartridge Tubing Kit - Consists of 20-, 30-, 40-, and 50-cm lengths of heat -formed tubing and all connectors
|
| 144717
|
Cartridge Tube Kit 100 - Cartridge coolant tubing (100 cm total length)
|
| 144711
|
Aperture, 100 x 800 µm (kit of 3)
|
| 144712
|
Aperture, 100 x 200 µm (kit of 3)
|
| 144829
|
EDA Cartridge and Adapter Kit - New EDA cartridge with all tubing, clips, seals, etc., and the adapter couplings. Cartridge is detector bypass type.
|
| 149044
|
Blank Cartridge CE/MS Kit Organic Solvent Resistant Cartridge
|
| 144822
|
EDA Capillary Adapter Assembly - EDA capillary adapter body, adapter nuts, seals, fittings, and tubing kit. Used to make existing MDQ detector window cartridges into EDA. No cartridge included.
|
| 144834
|
EDA Tubing Kit - Precut EDA tubing , buts, O-rings, and ferrules
|
| 144866
|
Double Seals with Clips (pkg. of 4)
|
| 144873
|
Single Seals with Clips (pkg. of 4)
|
| 721125
|
MDQ LIF Cartridge Stabilizer Plug for Use with LIF Detection System - Requires probe guide
|
| 721126
|
MDQ LIF Cartridge Probe Guide for Use with LIF Detection System - Requires stabilizer plug
|
| 144672
|
Electrode Replacement Kit - 2 screws, 20 rings, 2-pt wires
|
| 144673
|
Ejector Replacement Kit
|
| 359976
|
Coolant, 450 mL (quantity 1)
|
|
|
|
|
Large Volume Buffer Reservoir Kit
|
|
|
| Part No. |
Description |
| 144824
|
Large Volume Buffer Reservoir Kit - 2 large volume buffer reservoirs, 4 buffer reservoir lids, buffer reservoir removal tool
|
| 144826
|
Buffer Reservoir Replacement Lid
|
| 144858
|
Replacement Buffer Reservoir Lid Removal Tool
|
| 144865
|
Buffer Reservoir Replacement O-Rings (qty. 4)
|
|
|
|
|
eCAP Cartridge With Capillaries (Non-MDQ Systems)
|
|
Each Capillary cartridge below contains a fused-silica capillary and is designed with a prealigned aperture for on -column detection. Circulation ports permit flow of inert heat transfer fluid to ensure efficient temperature control. Capillary lengths listed are effective lengths from inlet to detector.
|
| Part No. |
Description |
| 727604
|
Capillary Cartridge
Includes tested fused-silica capillary, 50 cm length, 50 µm ID, 375 µm OD, 100 x 200 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
|
| 727605
|
Capillary Cartridge
Includes tested fused-silica capillary, 50 cm length, 75 µm ID, 375 µm OD, 100 x 200 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
|
| 727607
|
High Sensitivity UV Cartridge
Includes tested fused-silica capillary, 50 cm length, 50 µm ID, 375 µm OD, 100 x 800 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
|
| 727606
|
High Sensitivity UV Cartridge
Includes tested fused-silica capillary, 50 cm length, 75 µm ID, 375 µm OD, 100 x 800 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
|
| 760604
|
LIF Cartridge - Includes tested fused-silica capillary, 50 cm in length, 75 µm ID, 375 µm OD
|
|
|
|
|
eCAP Capillaries (Pre-Burned Windows)
|
|
Install in P/ACE Capillary Cartridge using Capillary Replacement Kit, P/N 338432, to perform separation and analysis of a variety of samples, including pharmaceuticals, industrial chemical, chiral drugs, nucleic acids, amino acids, proteins, and peptides. Capillaries can be trimmed to optimize speed/resolution.
|
| Part No. |
Description |
| 338453
|
Fused-Silica Capillary - 75 µm ID, 375 µm OD, 37 cm total length/20 cm effective length (qty. 3)
|
| 338475
|
Fused-Silica Capillary - 20 µm ID, 375 µm OD, 37 cm total length/20 cm effective length (qty. 3)
|
| 338451
|
Bare-fused silica capillary - qty. 3
|
| 338454
|
Fused-Silica Capillary - 75 µm ID, 375 µm OD, 67 cm total length/50 cm effective length (qty. 3)
|
| 338480
|
eCAP ssDNA 100 Capillary - 100 µm ID, 65 cm total length (qty. 1)
|
| 241521
|
eCAP SDS 14-200 Coated Capillary - 100 µm ID, 65 cm total length (qty. 1)
|
| 477431
|
eCAP DNA Capillary - 100 µm ID, 65 cm total length (qty. 1)
|
| 477431
|
eCAP Amine Capillary - 50 µm ID, 65 cm total length (qty. 1)
|
| 477432
|
eCAP Amine Capillary - 75 µm ID, 65 cm total length (qty. 1)
|
| 477441
|
ProteomeLab Neutral Coated Capillary - 50 µm ID x 45 cm total length
|
|
|
|
|
|
|
Extended length capillaries used for interfacing P/ACE with Finnigan MAT or SCIEX mass spectrometers. Install in Capillary Cartridge using Capillary Replacement Kit, P/N 338432.
|
| Part No. |
Description |
| 360800
|
CE-MS Capillary - 75 µm ID, 111 cm total length (qty. 3)
|
| 360801
|
CE-MS Capillary - 50 µm ID, 111 cm total length (qty. 3)
|
|
|
|
|
Untreated Capillary (No Pre-Burned Window)
|
|
|
| Part No. |
Description |
| 338472
|
Untreated Capillary - 5 meters in length, 50 µm ID, 375 µm OD
|
| 338473
|
Untreated Capillary - 5 meters in length, 75 µm ID, 375 µm OD
|
| 338474
|
Untreated Capillary - 5 meters in length, 100 µm ID, 375 µm OD
|
| 360804
|
Untreated Capillary - 5 meters in length, 20 µm ID, 375 µm OD
|
|
|
|
|
eCAP Blank Capillary Cartridge (Non-MDQ Systems)
|
|
Insert fused-silica or gel capillaries into this cartridge to run on the P/ACE system. Can accommodate capillary tubing from 20 cm to 120 cm in length. Requires Capillary Replacement Kit, P/N 338432, and Capillary Tubing.
|
| Part No. |
Description |
| 727608
|
eCAP Blank Capillary Cartridge - 100 x 200 µm aperture
|
| 338449
|
eCAP Blank Capillary Cartridge - 50 x 200 µm aperture
|
| 360692
|
LIF Cartridge Blank
|
| 727610
|
Blank High Sensitivity UV Cartridges - 100 x 800 µm aperture
|
|
|
|
|
eCAP Capillary Replacement Kit (Non-MDQ Systems)
|
|
Provides materials required to build your own cartridge (requires Capillary Tubing and Blank Cartridge) or rebuild your existing capillary cartridge (requires Capillary Tubing). Includes necessary tools, detailed instructions, and materials for building/rebuilding 25 cartridges. Tools and materials include : capillary alignment plate, cleavingstone, clamps, gaskets, sealants strips, plugs, tools, and capillary retaining tubing.
|
| Part No. |
Description |
| 338432
|
Capillary Replacement Kit
|
|
|
|
|
Consumables Kit (Non-MDQ Systems)
|
|
Replacement supplies for the Capillary Replacement Kit. This kit includes gaskets, sealant strips, plugs, and capillary retainer tubing as required for building/rebuilding 25 cartridges.
|
| Part No. |
Description |
| 338431
|
Consumables Kit
|
|
|
|
|
Labware Supplies for P/ACE System MDQ
|
|
|
| Part No. |
Description |
| 144980
|
Vials, 2 mL (qty. 100)
|
| 144657
|
Vial Holders - Required for use of Micro Vials (qty. 50)
|
| 144648
|
Vial caps, 2 mL (qty. 100) - red cap
|
| 970668
|
Vials, 0.5 mL (qty. 50) - blue cap
|
| 144649
|
Vial Caps, 0.5 mL (qty.50)
|
| 144709
|
PCR Vials (qty.50)
|
| 358821
|
Micro Vial Springs - Required for use of Micro Vials (qty. 10)
|
| 144656
|
PCR Vial Caps (qty. 50) - gray cap
|
| 144390
|
Buffer Tray 36 (2 mL Vials)
|
| 144543
|
Buffer Tray 48 (2 mL Vials)
|
| 144544
|
Buffer Tray 48 (0.5 mL Vials)
|
|
|
|
|
Miscellaneous Supplies for P/ACE System MDQ
|
|
|
| Part No. |
Description |
| 144672
|
Electrode Replacement Kit - 2 screws, 20 rings, 2-pt wires
|
| 144647
|
Coolant Filling Kit - Consists of syringe, coolant fill tool, and connecting tubing
|
| 144667
|
Deuterium Lamp Replacement
|
|
|
|
|
Labware Supplies for P/ACE 2000-5000 Series
|
|
The Autosampler of the P/ACE system accommodates up to 34 vials; 10 in the inner tray (for electrolytes) and 24 in the
outer tray (for samples, conditioning fluids and electrolytes). Each vial fits into a vial holder, then into the autosampler.
Custom-made vial caps prevent evaporation of buffers and samples during operation.
For oligonucleotide work, Mini Vials fit into the P/ACE 4 mL vials using the Mini Vial Springs. For microvolume work,
Micro Vials fit into the 4 mL vials using the Micro Vial Springs.
The countertop vial storage rack holds up to 40 vials in holders and 20 micro vials.
|
| Part No. |
Description |
| 358807
|
Glass Vials - 4 mL working volume for sample and electrolyte (quantity 100).
|
| 358818
|
Vial Holders - Two pieces fit into P/ACE autosampler to hold sample and electrolyte vials (quantity 10).
|
| 359079
|
Vial Caps - Seals vials during run (quantity 50).
|
| 360004
|
Vial Caps - Seals vials for storage (quantity 10)
|
| 338487
|
Mini Vials - For oligonucleotide work, polypropylene, 200-400 µL working volume (quantity 100).
|
| 338488
|
Mini Vial Springs - Required for use of Mini Vials (quantity 50).
|
| 358819
|
Micro Vials - For microvolume work polyolefin, 5-30 µL working volume (quantity 10).
|
| 358821
|
Micro Vial Springs - Required for use of Micro Vials (quantity 10).
|
| 359093
|
Vial Storage Rack - Holds 40 vials and 20 Micro Vials in holders (quantity 1).
|
| 359980
|
Micro Vial Autosampler Kit - Provided with each purchase of a P/ACE system. Includes 100 vials, 10 Micro Vials, 10 Micro Vial springs, 40 vial holders, vial storage rack, and 50 vial caps.
|
|
|
|
|
Temperature-Controlled Sample Tray Supplies
|
|
|
| Part No. |
Description |
| 727012
|
Vial Holder (package of 5)
|
| 727011
|
Ambient Vial Holder for Tray (package of 10)
|
| 727013
|
Polypropylene Vials, 200 µL - For cooled vial holder (package of 100).
|
|
|
|
|
Miscellaneous Supplies for P/ACE 2000-5000 Series
|
|
|
| Part No. |
Description |
| 359976
|
Coolant, 450 mL (quantity 1)
|
| 142205
|
Deuterium Lamp Assembly, P/ACE 5000 - Replacement part (quantity 1).
|
| 359058
|
Deuterium Lamp Assembly, P/ACE 2000 - Replacement part (quantity 1).
|
| 360671
|
LIF Fiber - Optic Cable (5000) (quantity 1)
|
| 927781
|
Nitrogen Tank Quick Connector (quantity 1)
|
| 360643
|
Primer: Introduction to Capillary Electrophoresis
|
| 266924
|
Primer: Micellar Electrokinetic Chromatography
|
| 726388
|
Primer: Introduction to the Theory and Applications of Chiral Capillary Electrophoresis
|
| 727484
|
Primer: Separation of Proteins and Peptides by Capillary Electrophoresis: Application to Analytical Biotechnology
|
| 538703
|
Primer: Introduction to Quantitative Applications of Capillary Electrophoresis in Pharmaceutical Analysis
|
| 607397
|
Primer: Separation of DNA by Capillary Electrophoresis
|
| 725036
|
Primer: High Performance CE of Carbohydrates
|
|
|
|
|
Buffer, Test Mixtures, Reagents and Filters For Work with Free-Solution Capillaries
|
|
|
| Part No. |
Description |
| 338425
|
Capillary Performance Test Mixture A - Benzoic acid, p-hydroxybenzoic acid, p-hydroxy-phenylacetic acid (quantity 20 mL).
|
| 501333
|
Performance Test Mix B for MDQ
|
| 338426
|
Capillary Performance Run Buffer A - 100 mM sodium borate, pH 8.3 (quantity 50 mL).
|
| 338424
|
Capillary Regenerator Solution A - 0.1 N sodium hydroxide (quantity 50 mL).
|
| 338433
|
Boric Acid, 0.4 M (quantity 50 mL)
|
| 338434
|
Sodium Tetraborate, 0.1 M (quantity 50 mL)
|
| 338437
|
Capillary Performance Test Kit
|
| 338436
|
Borate Buffer Kit - Includes boric acid solution, 0.4 M, 50 mL sodium tetraborate solution, 0.1 M (quantity 50 mL).
|
|
|
|
|
Filters for P/ACE 2000-5000 Series and System MDQ
|
|
Purchase of the P/ACE system includes 200 nm, 214 nm, 254 nm and 280 nm filters. Additional filters can be purchased for replacement or custom applications and are customer installed.
|
|
|
|
|
|
UV Filters Compatible with P/ACE System MDQ
|
|
|
| Part No. |
Description |
| 144430
|
Filter, 200 nm
|
| 144431
|
Filter, 210 nm
|
| 144437
|
Filter, 214 nm
|
| 144432
|
Filter, 220 nm
|
| 144433
|
Filter, 230 nm
|
| 144438
|
Filter, 254 nm
|
| 144434
|
Filter, 260 nm
|
| 144439
|
Filter, 280 nm
|
| 144435
|
Filter, 300 nm
|
| 144436
|
Filter, 360 nm
|
|
|
|
|
LIF Filters for P/ACE 2000-5000 Series LIF Detectors
|
|
|
| Part No. |
Description |
| 360672
|
LIF Detector Filter Holder
|
| 961640
|
LIF 488 nm Notch Filter
|
| 960323
|
LIF 520 nm Emission Band Pass Filter
|
| 890879
|
LIF 560 nm Band Pass Filter
|
| 725412
|
LIF 675 nm Emission Band Pass Filter
|
|
|
|
|
Validation
Instrument Certification
|
|
Assures regulatory agencies that instrumentation performs to Beckman Coulter's published specifications. The Instrument Certification Program includes specially trained engineers, calibrated testing equipment traceable to national standards, comprehensive documentation and re-certification after repair when necessary.
|
| Part No. |
Description |
| 144869
|
P/ACE MDQ Instrument Certification (OQ1)
|
| 144870
|
P/ACE MDQ OQ2, No Support Agreement
|
| 144688
|
P/ACE MDQ Certification (OQ 3)
|
|
|
|
|
Capillary Validation
|
|
|
| Part No. |
Description |
| 501306
|
Neutral Capillary Validation Pack
|
| 501305
|
Amine Capillary Validation Pack
|
|
|
|
|